Plan Number: T20PRE0062
Parcel: Unknown

Review Status: Completed

Review Details: PRESUBM MTG

Plan Number - T20PRE0062
Review Name: PRESUBM MTG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/12/2020 LOREN MAKUS ENGINEERING REVIEW Completed 1. Site is not in either a balanced or critical basin.
2. Water harvesting must be maximized.
05/12/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
05/19/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed * TFD Knox box required at main gate entrance.
05/19/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T20PRE0062 - 2432 N SPARKMAN BLVD - Site U-Haul Moving and Storage

There is an existing, inactive ¾” water service line from the existing 6” asbestos cement water main in N. Sparkman Blvd, that can supply potable water to this parcel.

the existing 6” asbestos cement water main in N. Sparkman Blvd, can also supply additional fire flow to this parcel, should the fire department consider that necessary.

After a water fixture unit count has been conducted for the project using the 2018 International Plumbing Code, and the fire flow requirements have been established by the local fire authority, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section to discuss:

The number and size of water service lines and water meters necessary to serve this development.

The advantages and disadvantages of installing the necessary water meters via Tucson Water’s Job Order Contract (JOC) process.

Tim Rowe
Tim.Rowe@TucsonAz.gov
Tucson Water
05/19/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed May 19, 2020
T20PRE0062
2432 N Sparkman
Zelin Canchola Transportation and Mobility Engineering

No adverse comments. Standard requirements will apply.

New driveway, and sidewalk along Sparkman will be required.
05/19/2020 GDAURIA1 COT NON-DSD FIRE Completed * TFD Knox box required at main gate entrance.
05/19/2020 GDAURIA1 COT NON-DSD FIRE Completed * TFD Knox box required at main gate entrance.
05/20/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting – T20PRE0062
Address: 2432 N Sparkman Bl
Parcel(s): 111-07-0070
Zoning: C-2
Existing Use: Unknown, Vacant buildings on site
Proposed Use: Personal Storage

TRANSMITTAL DATE: May 20, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposed use is Personal Storage, which is permitted in the C-2 zone subject to use-specific standards 4.9.10.C.3 & .6.
3. Building setbacks to the north and west do not appear to be met. Setbacks in this location: West (Sparkman) 20 ft or 1.5 times wall height, measured from street property line; North 1.5 times wall height; South and East 0 ft.
4. Clarification is needed at whether any office space associated with the storage use is proposed on the site. Additional standards may apply.
5. Clarification is needed regarding relationship to the existing adjacent site. Will this site function in conjunction with the existing site? If so, a development package encompassing the entire combined site is required. Additionally, a lot combination processed with Pima County is also required.
6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.