Plan Number: T20PRE0060
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION

Plan Number - T20PRE0060
Review Name: PREAPPLICATION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2020 LOREN MAKUS ENGINEERING REVIEW Completed The Engineering Section has no comment.
05/11/2020 GDAURIA1 FIRE REVIEW Completed
05/20/2020 PMCLAUG1 URBAN PLANNING REVIEW Completed APPLICABLE PLAN POLICIES:

Plan Tucson
LT28.1.2 Require telecommunications facilities be located, installed, and maintained to minimize visual impact and preserve views. Cabling and fiber optics should be installed underground where possible, and the visual impact of cellular towers should be a prime consideration in the City's acceptance and approval.

LT28.1.3 Improve the appearance of above-ground utilities and structures and extend access to high-tech wireless communications facilities throughout the city.

Esmond Station Area Plan
The Esmond Station Area Plan policies do not specifically address wireless communication facilities/cell towers. However, commercial policies relate to appropriate siting and compatibility of uses as follows:

Policy 1: Promote commercial developments at appropriate locations and in appropriate amounts within the area.

Policy 2: Ensure commercial development is compatible with surrounding uses.


AT&T Mobility is proposing a new 80'-tall WCF tower disguised as a broadleaf (eucalyptus) tree just north of the Union Pacific Railroad tracks, approximately ¼ mile west of Houghton Road and 1/3 mile south of Old Vail Road. The location of the WCF is to the east across Craycroft Road from Craycroft Elementary School. The nearest residential units are single family homes located approximately 2,000 feet to the north across Old Vail Road. The site location is well outside of the 400-foot Scenic Corridor Zone for Houghton Road.

Plan policy supports WCF that are located at appropriate locations and installed to minimize visual impact and preserve views. Given the distance to residential properties and the stealth design of the WCF, little or no impacts on residential uses are anticipated and views from these properties will not be negatively impacted.

The proposed tower site lease area is shown on the PDP to be 24 feet by 35 feet-4 inches (848 square feet) and will be enclosed by a 12-foot high decorative masonry wall finished to match the nearby dumpster enclosure wall. Service access is proposed by way of 20-foot wide access easement from the adjacent commercial development (Walmart) immediately to the east of the project site.

The proposed project site is located within the Approach Departure Corridor (ADC-3) of the Airport Environs Zone overlay for Davis Monthan Air Force Base. The applicant is advised to contact the base community planner from DMAFB to ensure there are no issues or concerns of compatibility with DMAFB operations.

Per Zoning Review comments:
"The Houghton Town Center PAD in section 2.B.1. states Permitted uses for the entire Property shall include all uses that are listed as permitted or as special exception uses in the I-1 zone of the City Unified Development Code (UDC), and as modified in this PAD. Then later in that same section also states Additional permitted uses shall include: Any use listed as permitted or special exception in O-3, C-1, C-2, C-3, and I-1 Zones."
05/26/2020 ELISA HAMBLIN ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Elisa Hamblin, AICP; Principal Planner
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T20PRE0060
Address: 10100 E Old Vail Rd
Parcel(s): 14118008L
Existing Zoning: PAD-36
Proposed Zoning: PAD-36
Existing Use: Vacant
Proposed Use: Wireless Communication

TRANSMITTAL DATE: May 26, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. This site is located in PAD-36 Houghton Town Center. The use appears to be permitted without a special exception procedure. Please verify with Entitlements staff, John Beall or Peter McLaughlin.
3. This site is within the Davis-Monthan Air Force Base Airport Environs Zone, ADC-3 and NCD-A. Please note, the ADC-3 has the following restriction found in UDC Article 5.6.8.c.1.d. “The maximum permitted building height is 62 feet from design grade elevation or the height limit of underlying zone, whichever is more restrictive;”
4. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
05/27/2020 BILLIE LEE COMMENTS COMMENTS Completed