Plan Review Detail
Review Status: Completed
Review Details: PRESUBM MTG
Plan Number - T20PRE0059
Review Name: PRESUBM MTG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/06/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Site is not in a balanced or critical basin. 2. Five-year threshold retention is required. (https://new.azwater.gov/sites/default/files/SS8-99Detention_Retention.PDF) 3. Northeast corner of the site is within a City of Tucson Flood Hazard Area. A floodplain use permit is required for development in this area. 4. Alignment of solid waste might need to be adjusted to facility approach by service vehicles. Loren Makus, EIT loren.makus@tucsonaz.gov |
| 05/06/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | 7.6.4. LANDSCAPE STANDARDS Minimum Width Street landscape borders must be a minimum of ten feet wide as measured from the street property line. On streets designated as Major Streets and Routes (MS&R), the street landscape border must be measured from the future MS&R right-of-way line as determined by Section 5.4.4, Establishment of MS&R Right-of-Way Lines and Gateway Routes. Located on Site Street landscape borders must be located entirely on site, except that, if approved by the City Engineer or designee, up to five feet of the required ten foot width may be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. If funded by the State of Arizona and a verification letter is granted, then Zoning requirements are not applicable. |
| 05/11/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | May 11, 2020 T20PRE0059 Zelin Canchola Transportation and Mobility No adverse comments or special requirements. |
| 05/11/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * If building >30' in height, Fire aerial access per TFC D105 to be provided. * Verify Fire Access to within 150' of all portions of the buiding. * Show fire underground on DP. * Additional hydrant requested at SW corner of entrance. |
| 05/13/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting – T20PRE0059 Address: 9290 E Golf Links Rd. Parcel(s): 136-33-148C Zoning: O-3 Existing Use: Vacant Proposed Use: Educational Use – Elementary and Secondary TRANSMITTAL DATE: May 13, 2020 COMMENTS: 1. Charter schools, similar to public schools, are not subject to zoning regulations. However, a verification letter from the State of Arizona is required with submittal. 2. Although formal site plan review is not required, submittal of a development package is recommended so that applicable fire, right-of-way and other standards may be reviewed. 3. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |
| 05/14/2020 | EHAMBLI1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | T20PRE0059 - 9290 E GOLF LINKS RD - SITE Legacy Traditional School · There is an existing 8” water main constructed under Plan No. 050-2011 just outside the east side of the property in a 15 ft. wide existing water line easement. · The site plan drawing does not show this existing water line, or existing water line easement. But it does show the construction of some identified and some unidentified features in this easement. Please be aware that vehicular access to all portions of this easement must be maintained. · There are also two 8” water line stubs extending from Plan No. 050-2011 onto this property in existing easements that have not been shown on the site plan: One at the north end, and one at the south end. What do you plan to do with those stubs? If they are to be abandoned, there are formal abandonment process that will need to be followed. · No fire flow requirements have been shown on the site plan. After a water fixture unit count has been conducted for the project using the 2018 International Plumbing Code, and the fire flow requirements have been established by the local fire authority, please contact Ray Munoz at 837-2207 in the Tucson Water New Services Section to discuss: o Potential points of connection to Tucson Water’s existing water distribution system. Please note that hydraulic modeling may need to be performed to verify which potential points of connection have the capacity necessary to serve the proposed development. o The number of water service lines, water meters, and meter sizes, necessary to serve this development. o The advantages and disadvantages of installing the necessary water meters via Tucson Water’s Job Order Contract (JOC) process. |