Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T20PRE0041
Parcel: Unknown

Address:
309 N PARK AV

Review Status: Completed

Review Details: PRESUBMITTAL MTG

Plan Number - T20PRE0041
Review Name: PRESUBMITTAL MTG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/03/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Landscape has no comment for SFR addition.

Note: Site is within a FEMA floodplain
03/04/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting - T20PRE0041
Address: 309 N Park
Parcel(s): 124062560
Zoning: R-2
Existing Use: Single-family residential
Proposed Use: (same)

TRANSMITTAL DATE: March 4, 2020

COMMENTS:
1. The proposal is for a 2-story addition to an existing single-family residence. This is a permitted use in R-2 zone, subject to use-specific standards 4.9.7.B.6, .9, & .10.
2. Clarification is needed on the proposed wall height (not building height) to the north, south and west. Assuming worst case scenario of 25 ft, the required setback is 16.75 ft. The 11.4 ft setback would allow a maximum wall height of 17 ft. The 12.6 ft setback would allow a maximum wall height 18.9 ft. A Design Development Option (DDO) may be requested for reduced setbacks.
3. Other development standards appear to be met.
4. It was assumed this submittal was for an expansion of an existing single-family residence with the same use proposed in the future. Should the proposal be for a group dwelling on multi-family use, different development standards will apply.
5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the formal review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
03/05/2020 LOREN MAKUS ENGINEERING REVIEW Completed T20PRE0041 - 309 N PARK AV
1. Site is within FEMA Special Flood Hazard Area Zone AE. Regulatory flood Elevation is approximately 2403.6.
2. Floodplain compliance requires one of the following:
a. Letter from the City of Tucson historic preservation officer indicating the improvements will not alter the contributing status of the property.
b. Elevation of the addition to the regulatory flood elevation and limit the opening between the existing structure and the addition to one standard door.
c. The cost of the improvements not exceeding half the value of the existing structure and the lowest floor no lower than the existing.
03/10/2020 SBEASLE1 COT NON-DSD TRAFFIC Completed No adverse comments. standards requirements will apply.
03/10/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
03/10/2020 SBEASLE1 COT NON-DSD FIRE Passed