Plan Review Detail
Review Status: Completed
Review Details: PRESUBMITTAL MTG
Plan Number - T20PRE0023
Review Name: PRESUBMITTAL MTG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/31/2020 | ANDREW CONNOR | LANDSCAPE | REVIEW | Completed | 7.6.4. LANDSCAPE STANDARDS Vehicular Use Areas The standards in this Section 7.6.4.B apply to all developments that provide more than four motor vehicle parking space. 7.6.5. SCREENING STANDARDS The purpose of screening is to provide visual barriers, noise reduction, and to provide privacy. When Required. Screening for individual land uses and zones must be provided as determined in Table 7.6.4-1 and in addition to the required landscape borders. Screening is not required between similar uses in accordance with Table 7.6.4-1. Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements. |
| 01/31/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | * Fire sprinklers required in new R-2s. * Portable fire extingishers required w/in 75. travel distance or in each unit. * Address numbers required at the street. * Yards in which bedroom emergency egress falls, must lead to the public way w/o needing a key or any special knowledge to open any gates w/in the pathway. |
| 01/31/2020 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 pm - T20PRE0023 - 1328 E HEDRICK DR - SITE Eight-unit apartment complex " If the fire department determines that a fire flow of 1500 gpm or greater is required for this project, please contact me and request that I verify the existing 6" water mains in this area can deliver the necessary fire flow without causing damage. Tim Rowe, Sr. Engineeering Associate Tucson Water, New Development Unit 310 W. Alameda St, Tucson, AZ 85701, (520) 837-2106 |
| 01/31/2020 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Completed | January 31, 2020 T20PRE0023 Zelin Canchola Transportation No Adverse comments. Standard requirements will apply for development Package. |
| 01/31/2020 | GDAURIA1 | COT NON-DSD | FIRE | Completed | * Fire sprinklers required in new R-2s. * Portable fire extingishers required w/in 75. travel distance or in each unit. * Address numbers required at the street. * Yards in which bedroom emergency egress falls, must lead to the public way w/o needing a key or any special knowledge to open any gates w/in the pathway. |
| 02/04/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | T20PRE0023 1. Solid waste container approach is acceptable. Recycle and waste containers recommended. 2. Retention is not required. Water harvesting must be maximized. |
| 02/06/2020 | ELISA HAMBLIN | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Elisa Hamblin, AICP; Principal Planner PROJECT: Thursday Pre-submittal meeting - T20PRE0023 Address: 1328 E Hedrick Dr Parcel(s): 113071800, 11307179B Zoning: R-2 Existing Use: Vacant Proposed Use: Multifamily development TRANSMITTAL DATE: February 5, 2020 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The proposal is for development of a vacant site to multifamily residential. The use is permitted in the zone, subject to use-specific standards 4.9.7.B.6, .9, & .10. 3. Based on an estimated lot size (from the subdivision plat) of 25,134 sq ft, eight multifamily units are permitted. 4. The required setbacks to the interior lot lines on the north, south, east and west is 10 ft or ¾ the wall height. Correction is required on the utility plan. 5. Other development standards (parking and lot coverage) appear to be met. 6. Additional information is needed on wall and building height. 7. Pedestrian access (sidewalk) is needed to Hedrick Dr. 8. Bike parking is required at the following standards: short-term 0.10 spaces per bedroom. Minimum requirement is 2 spaces. Long-term 0.5 spaces per bedroom. Minimum requirement is 2 spaces. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966. |