Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T20PRE0009
Parcel: Unknown

Review Status: Completed

Review Details: PRESUBMITTAL MTG

Plan Number - T20PRE0009
Review Name: PRESUBMITTAL MTG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2020 ANDREW CONNOR LANDSCAPE REVIEW Completed Section 7.6, Landscaping and Screening


Buildings Greater Than 10,000 Square Feet
On sites where the gross floor area of the existing building(s) is more than 10,000 square feet, expansion in square footage of land area, floor area, lot coverage, or vehicular use area as follows:
a. If the expansion is less than 25%, the standards of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning standards in effect at the time the existing development received zoning approval.
b. If the expansion is 25% or greater or if expansions as of February 15, 1991, cumulatively result in a 25% or greater expansion in land area, floor area, lot coverage, or vehicular use area, the standards of this section apply to the entire site.
Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-10.0.0, Landscape Plan Requirements.
01/15/2020 LOREN MAKUS ENGINEERING REVIEW Completed T20PRE0009 - 5255 E Broadway BL
1. Maximize water harvesting for new landscape areas.
01/16/2020 ELISA HAMBLIN ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Elisa Hamblin, AICP; Principal Planner

PROJECT: Thursday Pre-submittal meeting - T20PRE0007
Address: 5255 E Broadway Bl
Parcel(s): 12701008A
Zoning: C-1
Existing Use: Retail - General Merchandise, Commercial - Food Service
Proposed Use: Retail or Food Service TBD (new building)

TRANSMITTAL DATE: January 16, 2020

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. The proposal is to add a new building on an existing shopping center site. The new building is proposed to be either retail or food service uses. Retail - general merchandise sales is permitted, subject to 4.9.9.B.3 and 4.9.13.O. Food service is permitted, subject to 4.9.4.M.1 & 5 and 4.9.13.O.
3. As an existing site, parking is calculated for the entire shopping center. The site (including 3 existing buildings and 1 new building) would require approximately 408 parking spaces, which appears to be met with the proposal.
4. Provide an expansion calculation with submitted development package. This is a cumulative expansion of gross floor area since original development of the site, or last time the site met full code compliance. When 25% expansion is hit, the site must meet full code compliance for current development standards.
5. Provide setback dimensions on development package. The setback from Beverly Av will be 21 ft or the wall height, as measured from outside edge of adjacent travel lane.
6. Pedestrian access is required from both streets to the new building.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at elisa.hamblin@tucsonaz.gov or (520) 837-4966.
01/22/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Completed Standard requirements will apply.
01/28/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed
01/28/2020 SBEASLE1 COT NON-DSD FIRE Completed