Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T20PI00030
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/04/2021 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Reqs Change | We completed our review and found no issues or conflicts with the irrigation system; however, we would appreciate if you could please incorporate the following notes to the plans just in case the irrigation system is encountered during construction. Irrigation General Notes 1. All new and existing irrigation lines must be sleeved whenever its location will be under concrete sidewalk, ramps, driveways, etc. 2. DTM Streets Maintenance Division, Median Island/Irrigation Section must be contacted at 520-237-9561 when damaged is done to the irrigation system. 3. When damaged is done to the irrigation control wire the contract has two options: replace new wire between the nearest pit boxes or properly splice the wire and install a new pit box at the break. Thank you. Matt Sierras Transportation Superintendent City of Tucson Department of Transportation & Mobility Street Maintenance Division 520-400-3995 |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
| 02/04/2021 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | Please include signing and marking for trail crossing as attached. Blake Olofson, P.E. Traffic Engineering - Safety City of Tucson (520) 373-3798 Mobile Blake.Olofson@tucsonaz.gov |
| 02/04/2021 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
| 02/04/2021 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review | |
| 02/11/2021 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Reqs Change | DTM Landscape: Provide Low-Grow seed mix for area between MUP and Houghton Road or alternate ground cover. Clarify this on the plan. Provide Seed mix for area between MUP and Property line. Clarify this on the plan Has a native plant inventory been completed for the ROW to be disturbed? Thanks, David David Marhefka da’-vid mär-hef’-ka Landscape Architect City of Tucson Department of Transportation and Mobility (o) 520-837-6618 (m) 520-403-5074 |
| 02/22/2021 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 02/22/2021 | CRAIG SALTZMAN | DOT ENGINEERING | REVIEW | Reqs Change | 1) All sheets add to title block Plan No. U-2020-016 2) Sht. 1 of 5: Top center of sheet under Title add PIA No. T20PI00030 3) Sht. 1 of 5: Paving Notes 3 Unless specified. Remove: PAG Standard Specification for public improvements, section 406 Mix #2 Replace with the following: Asphaltic concrete shall conform to City of Tucson Mix #2 4) Sht. 1 of 5: Paving Note 19, Remove: “Ernie Encinas at (520) 791-3154” Replace with: Armando Bracamonte at (520) 792-3191 5) Sht. 1 of 5: Add recorded sequence to cover Sheet (plat, grading plan, etc.) 6) Sht. 5 of 5: Details B, C & F Call out City of Tucson Mix #2 7) Sht. 5 of 5: Detail C Asphalt Path Section: call out a 1ft. thickened edge. 8) Sht. 5 of 5: Detail B AC Paving Section: verify the paving section is the same Structural Paving Section call out on the Houghton Road Project. |
| 02/22/2021 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |