Plan Number: T20PI00029
Parcel: Unknown

Address:
2100 E AJO WY

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00029
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2021 ZELIN CANCHOLA DOT TRAFFIC REVIEW Reqs Change DTM Traffic Engineering

Comment(s) for consideration:

1. The combination bus pullout/driveway is not preferred. I don't know if any development code prohibits this configuration.

2. Restricting the eastern driveway to right-in/right-out/left-in (no left out) would be preferred.

Blake Olofson, P.E.
Blake.Olofson@tucsonaz.gov
520-837-6667
02/03/2021 GARY WITTWER DOT LANDSCAPE REVIEW Approv-Cond DTM Landscape:

1. Add a note to the plan. a. Contractor shall coordinate with COT Streets and Traffic Maintenance regarding irrigation in the median and shoulders. Contact Matt Sierras 520-400-3995.

David Marhefka
Landscape Architect
City of Tucson
Department of Transportation and Mobility
(o) 520-837-6618
(m) 520-403-5074
02/03/2021 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
02/11/2021 ERNIE ENCINAS DOT_ELEC REVIEW Approved
02/11/2021 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
02/11/2021 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review
02/22/2021 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
02/22/2021 CRAIG SALTZMAN DOT ENGINEERING REVIEW Reqs Change 1) All sheets add to title block Plan No. U-2020-017
2) Sht. 1 of 3: Top center of sheet under Title add PIA No. T20PI00029
3) Sht. 1 of 3: Paving Note 20, Remove: “Ernie Encinas at (520) 791-3154” Replace with: Armando Bracamonte at (520) 792-3191
4) Sht. 1 of 3: Add recorded sequence to cover Sheet (plat, grading plan, etc.)
This offsite work does not address the work shown for the bus pull out, the following addresses that work and adjustments needed prior to construction of:
1) Remove gutter pan from curb in the City of Tucson along Ajo Way (The City does not use a gutter pan due to the conflicts when milling and overlaying city streets).
2) Remove gutter pan adjacent to bus pull out along Ajo Way.
3) Align pedestrian pathway/ access ramps directly across from each other (remove the skewed path as shown). Also need to extend sidewalk to match new location of westerly access ramp directly across from eastern access ramp.
02/22/2021 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed