Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T20PI00027
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/27/2021 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Reqs Change | 1.) Clearly indicate that the irrigation control valves and mainlines (excluding roadway crossing) are located outside the public rights-of-way. Keynotes in the DP landscaping plans indicate to Install mainline and control valves outside of COT ROW but in next sentence say to install mainline 12" behind the sidewalk, which is in the ROW. 2.) Add the following Private Irrigation Within the Public ROW Notes City of Tucson, Department of Transportation Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way 1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways. 2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way. 3. The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member. 4. Minimize the number of roadway crossings. 5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting. 6. Irrigation lines shall be placed in ductile iron sleeves. 7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT. 8. HDPE continuous line (no joints under the pavement) 9. Irrigation lines shall have a minimum of thirty (30) inches of cover. 10. Detectable marking tape shall be installed. David Marhefka Landscape Architect City of Tucson Department of Transportation and Mobility (o) 520-837-6618 (m) 520-403-5074 |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
01/27/2021 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf |
01/27/2021 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
01/27/2021 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | |
01/27/2021 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | |
01/27/2021 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | January 27, 2021 SUBJECT: La Estancia Phase II, Parcel 1 Paving Plans PROJECT REVIEWER: Richard Leigh, DTM Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments. 1. Add the plan number "I-2020-028" in the title block of each sheet. 2. Add PIA activity number "T20PI00027" on coversheet. 3. Sheet 2: Paving Note 5 to indicate that the asphaltic concrete shall conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. 4. Sheet 2 through 16: Use current DTM title blocks. See Engineering Plan Template at: https://www.tucsonaz.gov/files/transportation/Engineering_Plan_Templates_Dec_2019.pdf 5. Sheets 3: Revise scupper detail to indicate placement of barricade railing along the back of the scupper. 6. Sheets 4: Provide a curb access ramp at the intersection of Via Casa De Campo and Paseo De Villalobos. Refer to COT TSM Section 10-01.3.3.E. 7. Sheets 7: Curb access ramps will have to be provided at the intersection of Paseo Del Cacapo Via Casa De Campo and Paseo Del Cachapo and Via Perfecta. Refer to COT TSM Section 10-01.3.3.E. 8. Sheet 7: Indicate placement of a driveway apron based on PAG S.D. 20 at the PC RRWRD Maintenance access road adjacent to lot 125 and indicate the placement of removable post barricades will be a minimum of one foot behind the sidewalk. 9. Sheet 11 & 13: An easement from the City will have to be obtained for the private irrigation lines crossing Via Perfecta and Via Casa De Campo. Additionally, the lines will have to comply with the following DTM guidelines. - Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways. - Lateral lines under constant pressure shall not be permitted in the public rights-of-way. - The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member. - Minimize the number of roadway crossings. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting. - Irrigation lines shall be placed in ductile iron sleeves. - Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT. - HDPE continuous line (no joints under the pavement) - Irrigation lines shall have a minimum of thirty (30) inches of cover. - Detectable marking tape shall be installed. - Curb shall be marked/stamped with "IS" (Irrigation System) and/or placard at back of curb. 10. Sheet 15: Gates approved by TFD need be provided to restrict access to the general public. 11. Sheet 16: Provide complete information for the slotted drain system. Include manufactures product numbers, metal gauge and coating, vane type and height, end sections, coupling banding other fittings. Also, provide complete installation details. The City of Tucson requires CMP to be encased in concrete. 12. Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf 13. Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov. |
01/27/2021 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
01/27/2021 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review |