Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T20PI00025
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/13/2021 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
01/13/2021 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf. |
01/13/2021 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | Please submit utility notification receipts. A list of utility companies that need to be notified of the proposed improvements in the public right-of-way at the following link. https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Mar27z.pdf |
01/13/2021 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | |
01/13/2021 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | |
01/13/2021 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | January 13, 2020 SUBJECT: La Estancia Phase II, Parcel 3 Paving Plans PROJECT REVIEWER: Richard Leigh, DTM Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments. 1. Add the plan number "I-2020-027" in the title block of each sheet. 2. Add PIA activity number "T20PI00025" on coversheet. 3. Sheet 2: Paving Note 5 to indicate that the asphaltic concrete shall conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. 4. Sheet 2 through 10: Use current DTM title blocks. See Engineering Plan Template at: https://www.tucsonaz.gov/files/transportation/Engineering_Plan_Templates_Dec_2019.pdf 5. Sheets 3: Revise scupper detail to indicate placement of barricade railing along the back of the scupper. 6. Sheets 4: Provide a curb access ramp at the intersection of Camino Estrana and Camino Dos Manos, in front of lot 82 or 83. Refer to COT TSM Section 10-01.3.3.E. 7. Sheets 7: Curb access ramps will have to be provided at the intersection of Paseo De Sambuca and Caminito Mambla. Refer to COT TSM Section 10-01.3.3.E. 8. Sheets 7: Curb access ramps will have to be provided at the intersection of of Paseo De Sambuca and Caminito Lacero. Refer to COT TSM Section 10-01.3.3.E. 9. Sheet 10: Indicate placement of a driveway apron based on PAG S.D. 20 at the PC RRWRD Maintenance access road adjacent to lot 43 and indicate the placement of removable post barricades a minimum of one foot behind the sidewalk. 10. Provide street and stop signs per the Pima County and City of Tucson 2020 Signing and Pavement Marking Manual, which can be found at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Transportation/Roadway%20Design/FINAL_PimaCounty_CityofTucson_SigningPavementMarkingManual2020_FirstEdition.pdf. 11. Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov. |
01/13/2021 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | Please submit utility notification receipts. A list of utility companies that need to be notified of the proposed improvements in the public right-of-way at the following link. https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Mar27z.pdf |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
01/13/2021 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review |