Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T20PI00017
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/29/2020 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Reqs Change | DTM Landscape: Please include the following notes to the plans as they are not on the Landscape Plans: City of Tucson Department of Transportation & Mobility Standard Notes for Planting in Right of Way 1. It is the owner's responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Unified Development Code Technical Standards Manual section 10. 2. It is the owner responsibility to keep a 5' wide (minimum) by 7' tall clear pedestrian access open across the entire property. 3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15' high clear zone over the travel lane. 4. Final plant locations must be in compliance with all utility setback requirements. 5. The owner understands that if the City of Tucson Department of Transportation & Mobility or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair. 6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities. 7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property (excluding water meter). 8. Contractor to obtain a ROW permit prior to construction within the ROW. David Marhefka Landscape Architect City of Tucson Department of Transportation and Mobility (o) 520-837-6618 (m) 520-403-5074 |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Needs Review | |
| 10/29/2020 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Reqs Change | Reviewer: Greg Orsini P.E. Greg.orsini@tucsonaz.gov DTM Traffic Engineering comments on the 9290 Golf Links Rd (LTS Tucson Campus 2021) signing and striping plans: 1. Sheet 1, Signing Note 1: should refer to 2009 MUTCD, as that is the latest 2. Sheet 1, Signing Note 6: please change sheeting type to Type XI 3. Sheet 1, Signing Note 9: design speed of Golf Links Rd is 45 mph, and posted speed is 40 mph 4.Sheet 3, Striping Note 5: design speed of Golf Links Rd is 45 mph, and posted speed is 40 mph 5. Sheet 3, Striping Note 8: please revise to 90 mil (0.090"), and not hot-sprayed. Note should be as follows: THE FINAL LONGITUDINAL STRIPING SHALL BE 90 MIL (0.090') THICK THERMOPLASTIC REFLECTORIZED STRIPING PLACED OVER THE TEMPORARY STRIPING WITHIN ยท14 TO 30 CALENDAR DAYS. AFTER COMPLETION OF THE FINAL PAVEMENT SURFACE, OR AS DIRECTED BY THE TRAFFIC ENGINEER. ALL OTHER MARKINGS SHALL BE APPLIED AT THE SAME TIME. TEMPORARY STRIPING SHALL BE PAINT. Quantity table on sheet 3 should be revised to match 0.090", as well 6. Sheet 3, Striping Note 9: please remove reference to hot-sprayed. Note should be as follows: ALL FINAL TRANSVERSE MARKINGS SHALL BE 90 MIL THERMOPLASTIC STRIPING (0.090"). ALL PAVEMENT ARROWS AND LEGENDS SHALL BE 90 MIL THERMOPLASTIC PAVEMENT MARKING (0.090"). EXTRUDED THERMOPLASTIC OR PREFORMED APLICATIONS MAY BE USED IF APPROVED BY THE TRAFFIC ENGINEER. 7. Sheet 3, Right Turn Lane signage: At Sta 18+67 and Sta 20+27, desired City signage for RTL is R3-5f on top of R3-5R 8. Sheet 3: please eliminate the WS6 striping that runs directly adjacent to the curb from Sta 17+82 to Sta 20+42 9. Sheet 3: Per Sheet 4-7 of PC/COT Pavement Marking Design Manual, end WG6(2x6) and WG8(2x6) striping at end of turn bay taper/start of right turn storage (Sta 18+67). Begin WS6 and WS8 solid stripes at this location. Their end location looks appropriate, but the WS6 has a typo in the station callout where it ends |
| 10/29/2020 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 10/29/2020 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Reqs Change | Provide 2 4" schedule 40 irrigation sleeves across proposed driveway. |
| 10/29/2020 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Approved | |
| 10/29/2020 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | September 22, 2020 SUBJECT: Offsite Improvement Plans for Project LTS Tucson Campus 2021 PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Add the plan number "U-2020-011" in the title block of each sheet. 2. Add PIA activity number "T20PI00017" on coversheet. 3. Add the project development plan number on coversheet. 4. Sheet 1: Revise Paving Note 4 to indicate that the asphaltic concrete shall conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. Indicate proposed mix type and provide a pavement structural detail. 5. Sheet 1: Revise title block to include signatory titles as included in COT DTM Engineering Template. https://www.tucsonaz.gov/files/transportation/Engineering_Plan_Templates_Dec_2019.pdf. 6. Sheet 3: Revise construction note 3 to indicate the proposed asphalt will match the existing pavement structural section per as-built plan I-89-21. 7. Sheet 3: The existing electrical cabinet located Sta. 20+10, 70 RT will have to be relocated outside of the site visibility triangle of the proposed driveway. 8. Sheet 3: Tie construction stationing to a survey monument. 9. Include striping and electrical plans to this plan. 10. Please Refer to redline drawings for additional comments and comment details. If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov. |
| 10/29/2020 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
| 10/29/2020 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review |