Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Plan Number: T20PI00015
Parcel: Unknown

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00015
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/24/2020 GARY WITTWER DOT LANDSCAPE REVIEW Completed
09/24/2020 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Needs Review
09/24/2020 ZELIN CANCHOLA DOT TRAFFIC REVIEW Completed
09/24/2020 ERNIE ENCINAS DOT_ELEC REVIEW Approved
09/24/2020 JIM FEMLING DOT STREET MAINTENANCE REVIEW Completed
09/24/2020 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Needs Review
09/24/2020 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Needs Review
09/28/2020 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change September 24, 2020

SUBJECT: Paving Plans for Saguaro Trails Block 6, Phase II

PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal.

1. Add the plan number “I-2020-015” in the title block of each sheet.

2. Add PIA activity number “T20PI00015” on coversheet.

3. Add Development Plan number on coversheet.

4. Add subdivision plat number on cover sheet.

5. Label and provide details for proposed curb transitions.

6. Label all curb BC’s and EC's with stationing, offsets and elevations.

7. Sheet 2: Revise note 3 to indicate that AC will conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. The surface layer shall be a PG 76-22TR+.

8. Sheet 9: “Alternate Sidewalk Location” detail This detail should be revised to provide a 2' buffer between the curb and sidewalk. TSM requires a 2’ buffer and this configuration will not work in areas where parking is permitted

If you have any questions, I can be reached at 520-237-8692 or emailed at Richard.Leigh@tucsonaz.gov.