Plan Review Detail
Review Status: Completed
Review Details: PIA - SUBMITTAL
Plan Number - T20PI00011
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2020 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Approved | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | COT STREETS DIVISION | Approved | |
| 08/19/2020 | ZELIN CANCHOLA | DOT TRAFFIC | REVIEW | Approved | |
| 08/19/2020 | ERNIE ENCINAS | DOT_ELEC | REVIEW | Reqs Change | Please see redline drawings by Gabriel Rascon. Gabriel Rascon Traffic Maintenance Superintendent Department of Transportation and Mobility Mobile: (520) 400-7656 Gabriel.Rascon@tucsonaz.gov |
| 08/19/2020 | JIM FEMLING | DOT STREET MAINTENANCE | REVIEW | Approved | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | COX COMMUNICATION | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Needs Review | |
| 08/19/2020 | RLEIGH1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Needs Review | |
| 08/21/2020 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Reqs Change | August 20, 2020 SUBJECT: Offsite Improvements Plan for Corbett Village PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal. 1. Add the plan number "I-2020-012" in the title block of each sheet. 2. Add PIA activity number "T20PI00011" to cover sheet. 3. Add subdivision number to coversheet. 4. Sheet 3: The future 76' right-of-way for 29th Street needs to be divided equally between the existing roadway centerline. The future right-of-way should be depicted 38' north of the centerline of 29th Street. 5. Sheet 3: Provide a dimensioned detail of the NE corner of Sahuara Ave. and 29th Street. Show existing streetlight pole in relation to curb access ramp. 6. Sheet 3: Show proposed cross slopes in the pedestrian crosswalk areas at the new roadways of the subdivision. 7. Sheet 3: Indicate that the depressed curb will be replaced with vertical curb between Sta. +/- 15+00 and 15+50, Lt 29th Street. 8. Sheet 6: The streetlight pole located at the NW corner of 29th St and Sonoita Ave will have to be located outside of the sidewalk. 9. Please Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or emailed at Richard.Leigh@tucsonaz.gov. |
| 08/21/2020 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 08/21/2020 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |