Plan Number: T20PI00008
Parcel: Unknown

Address:
1002 E 36TH ST

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00008
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/27/2020 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
08/27/2020 RICHARD LEIGH DOT ENGINEERING REVIEW Approv-Cond August 27, 2020

SUBJECT: Offsite Improvements Plan for The Bridges B-I Sub, Second Review

PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review

RESUBMITTAL REQUIRED: DTM Permit Review Section has reviewed the subject PIA paving plan and recommends a conditional approval. The following comments need to be addressed and plans revised prior to submittal mylar plan set for review. Please email a PDF copy of the plan set for review and approval.

1. Provide placeholders for pedestrian access easements and roadway dedication recordation information.

2. Sheet 2: Revise note note 5 to indicate that AC will conform to PAG's Replacement Specification for Section 406 Asphaltic Concrete, dated December 12, 2019. The surface layer shall be a PG 76-22TR+ and a PG 70-10 for the underlying layers unless otherwise specified.
09/16/2020 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Completed
09/16/2020 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed Please submit utility notification receipts. A list of utility companies that need to be notified of the proposed improvements in the public right-of-way at the following link.

https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Mar27z.pdf
09/16/2020 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
09/16/2020 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed Please submit utility notification receipts. A list of utility companies that need to be notified of the proposed improvements in the public right-of-way at the following link.

https://www.tucsonaz.gov/files/transportation/UTLAWAREMEM_rev2019Mar27z.pdf
09/16/2020 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
09/16/2020 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed