Plan Number: T20PI00003
Parcel: Unknown

Address:
930 E 2ND ST

Review Status: Completed

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00003
Review Name: PIA - SUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2020 ZELIN CANCHOLA DOT TRAFFIC REVIEW Approved
06/05/2020 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Denied
06/05/2020 JIM FEMLING DOT STREET MAINTENANCE REVIEW Approved
06/05/2020 ERNIE ENCINAS DOT_ELEC REVIEW Approved
06/05/2020 RICHARD LEIGH DOT ENGINEERING REVIEW Reqs Change SUBJECT: Offsite Improvements Plan for The Maingate Phase V Mixed Use

PROJECT REVIEWER: Richard Leigh, TDOT, TDOT Eng. Review

RESUBMITTAL REQUIRED: TDOT Permit Review Section has reviewed the subject PIA paving plan and does not recommend approval at this time. The following comments need to be addressed and plans revised prior to resubmittal. Please include a response letter addressing the following comments and return redlined drawings with subsequent submittal.

1. Add the plan number "I-2020-008" in the title block of each sheet.

2. Add PIA activity number "T20PI00003" on cover sheet.

3. Add project's development plan on cover sheet.

4. Use latest TDOT engineering plan template for this plan set. The latest TDOT engineering plan template can be found at https://www.tucsonaz.gov/tdot/engineering. Additionally, include Record Document block.

5. Sheet 1: Revise General and Paving Note #5 to indicate the use of City of Tucson Mix #2.

6. Sheet 1: Remove General and Paving Note #2. Note is not applicable to this project.

7. Sheet 1: Revise General and Paving Note #23 to change Street and Traffic Facilities contact to Gabriel Rascon.

8. Sheet 1: Revise General and Paving Note #28 to reference geotechnical report for this project.

9. Sheet 3: Revise drawing to provide a curb access ramp/ramps at the SE corner of 2nd Street and Tyndall Ave that accommodates N&S and E&W bound pedestrian traffic.

10. Sheet 3: Callout and provide complete details for the proposed hardscape within the public right-of-way.

11. Sheet 3: Provide sections for sections callouts 2 and 3.

12. Sheet 3: Callout and provided complete details for the proposed scuppers and other drainage improvements along 2nd Street.

13. Please Refer to redline plans for additional comments and comment details
06/05/2020 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Denied
06/05/2020 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Denied
06/10/2020 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change DTM Landscape:
1. There appears to be a conflict with the trees and water line setbacks planted along 2nd in the ROW. https://www.tucsonaz.gov/files/transportation/files/setbacks.pdf
2. There appears to be a conflict with the tree on east side of 2nd and an historic light.
3. Please add the notes for irrigation and planting in the ROW to the plans.
a.
City of Tucson, Department of Transportation and Mobility
Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way
1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways.
2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way.
3. The HOA will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member.
4. Minimize the number of roadway crossings.
5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting.
6. Irrigation lines shall be placed in ductile iron sleeves.
7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by DOT&M.
8. HDPE continuous line (no joints under the pavement)
9. Irrigation lines shall have a minimum of thirty (30) inches of cover.
10. Detectable marking tape shall be installed.
11. Curb shall be marked/stamped with "IS" (Irrigation System) and/or placard at back of curb.

b. City of Tucson
Department of Transportation & Mobility
Standard Notes for Planting in Right of Way

1. It is the owner's responsibility to keep the Sight Visibility Triangles (SVT), and the pedestrian access area clear of vegetation at all times, per Unified Development Code Technical Standards Manual section 10.
2. It is the owner responsibility to keep a 5' wide by 7' tall clear pedestrian access open across the entire property.
3. It is the owner responsible to keep vegetation from growing past the curb line clear, and keep a 15' high clear zone over the travel lane.
4. Final plant locations must be in compliance with all utility setback requirements.
5. The owner understands that if the City of Tucson Department of Transportation & Mobility or any utility company needs to work within the ROW in the landscaped area, plants and irrigation may be destroyed without replacement or repair.
6. The owner takes full liability for this landscape and irrigation, and any damage to roadway, sidewalk and utilities.
7. The only private irrigation equipment that is allowed within the ROW are lateral lines, tubing and emitters that are not under constant pressure. All other equipment must be on private property (excluding water meter).
8. Contractor to obtain a ROW permit prior to construction within the ROW.

4. Please show the trees and irrigation on the PIA plans.
5. There appears to be a conflict with the fire hydrant clearance and plants.
6. Please add the notes found on top of the sheet L2.1 of the Development Package pertaining to legal agreements and irrigation in the ROW requirements on the plans.
7. Place riprap at curb openings to prevent smaller landscape rock from flowing onto pavement and gutter.

Thanks,

David



David Marhefka
d?'-vid mär-hef'-ka
Landscape Architect
City of Tucson
Department of Transportation and Mobility
(o) 520-837-6618
(m) 520-403-5074
06/10/2020 RICHARD LEIGH PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Completed
06/10/2020 RICHARD LEIGH PIA COORDINATOR OUT TO CUSTOMER Completed