Plan Number: T20PI00002
Parcel: Unknown

Address: Unknown

Review Status: Active

Review Details: PIA - SUBMITTAL

Plan Number - T20PI00002
Review Name: PIA - SUBMITTAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
02/11/2021 GARY WITTWER DOT LANDSCAPE REVIEW Reqs Change DTM Landscape:

1. The Irrigation notes to be added to the plans in the comment response letter are not the notes that are on the plan. Please add the correct notes.

City of Tucson, Department of Transportation and Mobility
Requirements for placement of Private Irrigation Facilities Roadway Crossings within the Public Rights-of-Way
1. Private irrigation facilities roadway crossings will only be permitted in residential roadways and NOT permitted in arterial or collector roadways.
2. Lateral lines under constant pressure shall not be permitted in the public rights-of-way.
3. The HOA/Owner will register private irrigation facilities placed in the public rights-of-way with Arizona 811and become an Arizona 811 Blue Stake Inc. member.
4. Minimize the number of roadway crossings.
5. Sleeves must be in a recorded easement (easement width is dependent on what is needed for installation and/or repairs). To the extent possible, the easements should be created at the time of development/platting.
6. Irrigation lines shall be placed in ductile iron sleeves.
7. Sleeve should extend beyond the right-of-way (into private property), unless otherwise approved by TDOT.
8. HDPE continuous line (no joints under the pavement)
9. Irrigation lines shall have a minimum of thirty (30) inches of cover.
10. Detectable marking tape shall be installed.
11. Curb shall be marked/stamped with "IS" (Irrigation System) and/or placard at back of curb.



Thanks,

David

David Marhefka
d?'-vid mär-hef'-ka
Landscape Architect
City of Tucson
Department of Transportation and Mobility
(o) 520-837-6618
(m) 520-403-5074
02/17/2021 CRAIG SALTZMAN DOT ENGINEERING REVIEW Approved
02/19/2021 RLEIGH1 UTILITY CLEARANCES COT STREETS DIVISION Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES COX COMMUNICATION Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
02/19/2021 RLEIGH1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
12/14/2020 ANY PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSSADOR Active Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines
12/14/2020 ANY PIA COORDINATOR OUT TO CUSTOMER Active Please submit utility notification confirmation for the utility companies listed on the PIA utility notification list. The list can be found at: https://www.tucsonaz.gov/tdot/private-improvement-agreement-guidelines