Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM09322
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/14/2021 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
01/14/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Completed | |
01/21/2021 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: T20CM09322 Balcony and Fireplace 1st Review 3134 E 26th St. TRANSMITTAL DATE: 01/15/2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: In the PAD-12 zone the minimum perimeter yard setback on the south property lines is 5’. The proposed fireplace does not meet setback requirements. As a detached accessory structure a neighbor sign off may be used to reduce perimeter yard setbacks required for the fireplace.. If you elect to use the neighbor signoff provide the following statement on the plot plan for each setback reduction and have your neighbor sign and date: "My Name is __________________and I am the owner of the property located at __________________. I have reviewed the site plan and I have no objection to structure being located or constructed 5'-0" from the property line as depicted on the site plan. If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
01/21/2021 | SROGERS2 | ENGINEERING | REVIEW | Passed | |
02/17/2021 | JVINCEN1 | FIRE | REVIEW | Reqs Change | This residence will have a “fire-flow calculation area”(2018 IFC Appendix B, Section B102 and 105.1) greater than 3,600 sq. ft.: therefore this house will require a residential sprinkler system unless the fire flow in the nearest hydrant is a minimum of 2,000 GPM for 2 hours duration at 20 psi residual pressure. Contact Tucson Water engineering for a hydraulic analysis. Provide notes on plan regarding verification of fire flow. If a system will be installed, residential or quick response sprinklers shall be used. The sprinkler system may be connected to the domestic water supply, provided the required design density can be met. Be advised that Tucson Water will not allow a residential sprinkler system to be supplied by a 5/8" meter. A minimum of ¾” meter will be required by Tucson Water. Residential fire sprinkler system shall be installed in accordance with the 2018 IFC and NFPA 13D. |