Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T20CM09309
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2021 | NICHOLAS ROSS | ZONING | REVIEW | Reqs Change | Zoning cannot conduct a review until a site plan meeting minimum requirements is submitted. A fully dimensioned site plan (not an aerial photograph) shall show project address including suite numbers and legal description. All easements with dimensions, lot area, north arrow, and scale. Location of all property lines, structure to property line setback dimensions (existing and proposed), proposed and existing utility meters, public sewer connections, sump pumps, back flow devices, and fire hydrant locations. Please provide street names for all adjacent streets, a fully dimensioned parking plan including tabulation of existing, proposed and required parking spaces. For an example of a residential site plan please visit: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf |
| 03/15/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide an Arizona Engineer stamped plan set for the fabricated metal carport for validating wind load compliance. Provide a complete plan set for the patio cover. This roof structure requires a 3 foot separation from the property line or a one-hour rated fire barrier in compliance with 2018 IBC Table 721.1(2), Items 15. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/16/2021 | PCAMARE1 | OUT TO CUSTOMER | Completed |