Permit Number: T20CM09298
Parcel: 117061370

Address:
122 N JACOBUS AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM09298
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/19/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed
04/26/2021 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T20CM09298
122 n Jacobus Ave
Attached Studio Addition
Residential (2nd Review)

TRANSMITTAL DATE: April 26, 2021

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-3 zone (UDC 4.7.12). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2), subject to Use Specific Standard 4.9.7.B.6.

Perimeter yard setbacks are based on a wall height as measured from design grade to the highest point of the wall, see UDC Article 6.4.5.B and Figure 6.4.5-A.

1. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 22’-9” the required perimeter yard setback from the proposed studio addition to the north and east property line is 15’-2”, proposed setback to the north and east property line is 1’-0”.
The DDO process is a separate submittal from the building plan. DDO requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf, and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”.

If you have any questions about this transmittal, please contact Elisa Hamblin, (520) 837-4966 or Elisa.Hamblin @tucsonaz.gov