Review Date Reviewer's Name Type of Review Description Status Comments
04/19/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM09281
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits

Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits

SITE PLAN:

1. Roof projections may not extend to a point closer than 2 feet from the property line. Show an overhang extending into the three foot fire separation distance to property line with one hour fire-resistive protection on the underside, R302.1 Exception 2.
2. Individual dwelling units in duplexes must be separated by 1-hour fire-resistance rated assemblies from floor to bottom of roof sheathing, R302.3. Provide a detail or notation showing compliance with R302.3.

STRUCTURAL PLANS:

1. Provide complete roof framing plan. Show size, spacing and span of all framing members, trusses, joists, rafters, beams and blocking with appropriate load carrying capacity, R301.1.

Please contact the plans reviewer if you have any questions:
Ken Van Karsen
(520) 837-4912 PDSD-Residential@tucsonaz.gov
City of Tucson Residential Plan Review
06/02/2021 STEVE SHIELDS ZONING REVIEW Reqs Change P&DS TRANSMITTAL


FROM: Nick Ross

PROJECT:
7662 N Sugarberry Dr
New Shed
T20CM09281


TRANSMITTAL: June 4, 2021


COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).


This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-3).

The minimum setback is the greater of ten (10) feet, or three-quarters (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The proposed wall height of the shed is ten (10) feet which requires a ten (10) foot setback from the northwest property line. Applicant is proposing a setback of three (3) feet. A DDO is required.