Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM09145
Parcel: 129072110

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM09145
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2021 ANDREW CONNOR NPPO REVIEW Passed
01/19/2021 PC_JEDER1 BUILDING-RESIDENTIAL REVIEW Reqs Change 1. It is the responsibility of the applicant submitting for permitting to verify that the roof on which the equipment is to be installed was legally permitted, is in good structural condition, and otherwise provides for a minimum residual load capacity meeting or exceeding 4 psf. 72 lbs point-load is being proposed, this is over the allowable prescriptively.

2. Uplift on panels: It is the responsibility of the applicant submitting for permitting to comply to the uplift structural calculation.

3. Submit for review and approval items 1 and 2 above that is prepared by an Arizona Structural Engineer registrant.
12/30/2020 NMARTEL1 ZONING REVIEW Approved
12/30/2020 DTRAMME1 ENGINEERING REVIEW Passed