Permit Number: T20CM09072
Parcel: 129052540

Address:
3001 E 18TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM09072
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/24/2022 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change The westside porch is located within the 3 foot fire separation distance to the property line. Therefore, show a full length and full height 1-hour rated fire wall parallel with the property line. Show he fire barrier wall in contact with the porch roof without openings. The roof may not overhang beyond the wall. Detail the wall foundation and composition showing 2018 IRC compliance.
07/07/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review Section

PROJECT: T20CM09072
3001 E 18th St. – R-1
Work without permits
Residential (3rd Review)

TRANSMITTAL DATE: July 7, 2022

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.1 - .9, & .11.

Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.

Perimeter yard setbacks for porch type structures are measured from the post supporting the roof structure as long as the roof does not overhang more than 2’-0”.

COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A).

1. Based on a wall height less than 9’-0” the required perimeter yard setback from the east porch structure is 6’-0”, proposed setback is 4’-9”.

2. Based on a wall height less than 9’-0” the required perimeter yard setback from the west porch structure is 6’-0”, proposed setback is 1’-2”.

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

3. Based on a wall height less than 9’-0” the required front street perimeter yard setback from the carport structure is 20’-0”, proposed setback from the allowed 2’-0” overhang is 11’-4”.

A Design Development Option (DDO) must be submitted and approved to reduce the required setback,
DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

Zoning acknowledges that a DDO application was submitted with the building plans but as prior comments were not addressed correctly it cannot be submitted to the DDO section for review as submitted. Zoning modified the plans to reflect the correct required information. Zoning has emailed a copy of the modified building plan pdf file to, valdez6308@gmail.com, This modified plan will need to be submitted with your DDO package. Submit the DDO as the direction state above. If the DDO is approved you will need to resubmit the modified plans provided to you.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.