Permit Number: T20CM09072
Parcel: 129052540

Address:
3001 E 18TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM09072
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2021 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change Provide a complete plan set showing 2018 IRC compliance including post, beam, rafter and foundation locations and sizing.

Identify each structure requiring permit on the site plan with size. Label each framing plan and detail with the same identification. Show size and type of each structrual fastener between the footer to the dwelling.

A carport or porch requires a clear 3 foot fire separation distance to the property line unless the structure includes a one-hour rated wall that is placed at the edge of the roof overhang. See IBC Table 721.1(2), Items 15-1.1 to 16-1.3 for a listing of fire rated materials.

A structural engineer may provide an analysis and sealed plans for structures not built with 2018 IRC minimum requirements.
12/30/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM09072
3001 E 18th St.
Work without permits
Residential (1st Review)

TRANSMITTAL DATE: December 30, 2020

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.1 - .9, & .11.

1. Provide a plot plan that is readable and meets the residential plot plan requirements found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
12/30/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/30/2020 SSHIELD1 NPPO REVIEW Passed