Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T20CM08990
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/19/2021 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 01/26/2021 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Reqs Change | 1. General: Please provide a site plan with the existing building and new awning located. 2. General: The drawings are stamped by a structural engineer with the statement that this awning is reviewed for compliance to the 2012 IBC. The current City of Tucson code is the 2018 IBC. Please revise and review for that code. 3. General: The structural engineer's seal expired on 6-30-16. Please update that license expiration. 4. General: A code analysis should be added to the drawings. This analysis should state the awning construction type, the awning square footage, and the awning occupancy classification, along with additional information as required by the 2018 IBC Section 107.2. Include information for the existing building (construction type, square footage, and occupancy classification). 5. General: Please provide written responses to all review comments. |
| 01/26/2021 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 01/29/2021 | SAMUEL ROGERS | ZONING | REVIEW | Reqs Change | FROM: Samuel Rogers PDSD Zoning Review Section PROJECT: T20CM08990 Aluminum Awning - 1st Review 3110 N 1st Av. TRANSMITTAL DATE: 01/29/2021 DUE DATE: 01/25/2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: All structures proposed on commercial sites must be approved on a Development Package prior to the building permit’s approval. For development package info see below: Development Package Application: https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf Development Package Submittal checklist: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf Presubmittal Application (not required): https://www.tucsonaz.gov/files/pdsd/forms/Thursday_Pre-Submittal_Meeting_Application.pdf 02. COMMENT: Additional comments may be applicable once the development package is issued. If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans |
| 02/01/2021 | JPEELDA1 | FIRE | REVIEW | Approved | Folder is empty. Need plans to review. |
| 02/12/2021 | LOREN MAKUS | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/16/2021 | PCAMARE1 | OUT TO CUSTOMER | Completed |