Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T20CM08956
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Provide a note on the plans to indicate that backwater valves will be required for lots 6, 7 and 8 when future plumbing activities take place because the rim elevation of the next upstream sanitary manhole is less than 12" below the proposed first floor elevations. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/06/2021 | PCAMARE1 | OUT TO CUSTOMER | Completed |