Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM08855
Parcel: 105102680

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T20CM08855
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2021 JPEELDA1 FIRE REVIEW Approved
01/12/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Provide structural calculations for the mounting shelf for the water heater (approximately 560 pounds) to show that the building structure can safely support the water heater. Reference: Section 301.2, IPC 2018.
2. Verify that the Pima County Regional Wastewater Reclamation Department will allow the floor drains from the boba production area and prep sink to bypass the grease interceptor. Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson.
01/12/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Reqs Change 1. The ventilation calculations refer to a coffee station. This seems to be more like a kitchen, as the architect has labeled it. Revise the ventilation calculation as needed. Reference: Section 403.3.1.1, IMC 2018.
2. Provide general room exhaust for any cooking appliance (e.g. convection oven, induction range, waffle bakers, etc.) that does not require the installation of a Type II hood. The minimum exhaust rate shall be 0.70 CFM per square foot, using a minimum area of 100 square feet for each individual appliance. Reference: Section 507.1, exception 2 and 507.3, IMC 2018.
01/12/2021 ROBERT SHERRY WATER REVIEW Completed
01/13/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
01/19/2021 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
01/26/2021 SAMUEL ROGERS ZONING REVIEW Reqs Change FROM: Samuel Rogers
PDSD Zoning Review Section

PROJECT: T20CM08855
TI – Interior Remodel and Change of Use to Food Service - 1st Review
4246 N 1st Av

TRANSMITTAL DATE: 01/26/2021

DUE DATE: 01/19/2021

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: Add “Proposed Use: Food Service – subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O


If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans
02/11/2021 STANTEC BUILDING-COMMERCIAL REVIEW Needs Review
12/18/2020 DTRAMME1 ENGINEERING REVIEW Passed