| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/25/2021 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Completed | |
| 03/25/2021 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Comment not addressed. [Third comment: The hot water connection for the lavatories located in public restrooms is not within allowable distance from the hot water source: 24” for ½” pipe, 6” for ¾” pipe.] [Second comment: Comment not addressed. [Initial comment: Verify that the distance from the hot water source to the hot water termination for the public lavatories complies with the requirements of Section C404.5, IECC 2018.] |
| 03/25/2021 | ROBERT SHERRY | WATER | REVIEW | Completed | |
| 03/31/2021 | ARUIZ1 | ZONING | REVIEW | Needs Review |