Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM08686
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2021 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 01/27/2021 | PCAMARE1 | ENGINEERING | REVIEW | Passed | |
| 02/03/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM08686 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Update the code reference on the plans from 2012 to 2018 on sheet #1 & 3. SITE PLAN: 1. Indicate the location and size of the water line from property line (meter) to building, R106.1.1. Show an existing or upgraded 1” line to the water heater. Minimum size for a two bathroom building is usually 1”, P2903.7. FLOOR PLANS: 1. Notate all walls for removal and any openings for enclosure, R106.1.1. 2. Provide a landing with minimum 36” depth at the front door, R311.7.6. STRUCTURAL PLANS: 1. Provide a complete roof framing plan. Include the living room addition, R801.2. PLUMBING PLANS: 1. Provide protection of (water heater) equipment located outdoors with an exterior rated enclosure, G2406.3. MECHANICAL PLANS: 1. Show dryer vent size and location for venting to exterior, M1501. 2. Show the existing bathroom (without a window) with an exhaust fan either existing or proposed, R303.3 and M1505. ELECTRICAL PLANS: 1. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. Update note #2 with “bedroom” limitation. 2. Show or notate a disconnect means or a locking breaker for the water heater, E4101.5. OUTDOOR LIGHTING CODE 1. Show the proposed fixture as full cut-off FCO style or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 02/04/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved |