Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM08452
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/25/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM08452 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Provide a site plan showing all buildings and the electrical service panel, R106.1.1. Show the point of connection of proposed electrical feeder line to the utility service for verifying correct sizes and necessary upgrades. ELECTRICAL PLANS: 1. Provide an electrical floor plan of new switch, light, and receptacle outlets, E3702.2. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
| 04/08/2021 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | FROM: Elisa Hamblin, AICP PDSD Zoning Review PROJECT: T20CM08452; Shipping container storage Building Plans (2nd Review) 364 E Calle Arizona – R-2 Zone TRANSMITTAL DATE: April 8, 2021 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review comments were addressed. The following comments were not addressed. 1. Provide a plot plan that meets minimum standards. An example plot plan with instructions can be found online: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf. 2. Provide dimensioned elevations for all proposed structures on site to determine appropriate setbacks. If you have any questions about this transmittal, please contact me at Elisa.Hamblin@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised building plans |