Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM08386
Parcel: 108203100

Review Status: Active

Review Details: 3RD PARTY REVIEW - RESIDENTIAL

Permit Number - T20CM08386
Review Name: 3RD PARTY REVIEW - RESIDENTIAL
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
12/01/2020 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW RECEIVED
12/01/2020 ANY 3RD PARTY REVIEW-COMMERCIAL AT 3RD PARTY OFFICE Active
12/02/2020 SSHIELD1 ENGINEERING REVIEW Passed
12/02/2020 ANDREW CONNOR NPPO REVIEW Passed
12/02/2020 STEVE SHIELDS ZONING REVIEW Reqs Change FROM: Steve Shields
Site Section Manager

PROJECT:
T20CM08386
4142 N Fortune Loop
Attached SFR

TRANSMITTAL: December 2, 2020
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

1. Along site boundaries the required perimeter yard setback is based on UDC Table 6.3-2.A. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing the property line. Perimeter yard setbacks are based on a wall height measurement from the highest point of the wall to design grade. Based on a wall height of 22’-6” the required perimeter yard setback from the proposed structure to the west property line is 15’-0”, proposed perimeter yard setback is 10’-0”.

2. The drawing files shall be resubmitted as a single multi-page PDF file on your next submittal.