Review Date Reviewer's Name Type of Review Description Status Comments
01/06/2021 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T20CM08269
Residential Project
January 06, 2021
The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.
1. Please resubmit the plans conforming to the requirements of the residential plot plan found at the following link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf
a. Zoning is unable to confirm the extent of the project. If the only work is exterior, and there are no walls or structures being added to the property, zoning can approve. If there is more work being done zoning will review further. Please submit a site plan showing the extent of the work being done.
If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
11/24/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM08269
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans.

SITE PLAN:

1. Indicate the location of the altered buildings on the property, R106.1.1.

FOUNDATION PLANS:

1. Show exterior footings at least 12” below the undisturbed ground surface, R403.1.4.
2. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12” width and 12” below the undisturbed ground surface, R403.1.

SECTIONS - DETAILS:

1. Specify veneer anchoring with ties spaced 24” O.C. horizontally & vertically, R703.2 & R703.7.
2. Show 1” air space between sheathing and veneer R703.8.

ELECTRICAL PLANS:

1. Designate the circuit number at the location of each light fixture and switch, E3404.12.

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
12/01/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/22/2020 ANDREW CONNOR NPPO REVIEW Passed