Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM08267
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | The 4 x 8 beam is undersized for a 14' span. Provide structural details showing code compliant materials and fasteners from the foundation to the roof covering of new exterior walls. Include the foundation dimensions and floor separation from grade. Show rating of insulation both walls and ceiling. New exterior walls require compliant attachment to a foundation with minimum 6" spacing above exterior grade. The bedroom requires a heating appliance and smoke detector at the dining room side of door. |
| 11/30/2020 | SBLOOD1 | ENGINEERING | REVIEW | Passed | |
| 12/10/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 12/17/2020 | NMARTEL1 | ZONING | REVIEW | Approved |