Permit Number: T20CM08175
Parcel: Unknown

Address:
4318 N WEGNER LN

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM08175
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/08/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change T20CM08175
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

Consolidate pages of construction plans into a single .PDF file as prescribed at the PDSD web site. https://www.tucsonaz.gov/pdsd/online-permits

ELECTRICAL PLANS:

1. A building/dwelling shall be supplied by a single service, NEC 230.2 & E3601.2.
2. Provide an electrical riser diagram showing each distribution panel and feeder conductor size, E3403.
3. Provide a panel schedule showing panel size, circuit numbers, ampacity, wire size and general description, E3404.13 & E3706.2. Show exterior cables with appropriate ratings for exposure.
4. Provide a minimum feeder conductor of 60 AMP for accessory structures and conductors with minimum rating of #4 copper 60 degree C, E3602.1 & E3705.1.
5. Revise the electrical load calculations following Table E3602.2 for sizing the general usage loads. Show 3 watts per square foot of floor area. Show 1500 watts for each 20A appliance and laundry circuit. Show nameplate entries for each appliance.
6. Verify water heater circuit size, E3702.11. Appliances may require 240 volt circuits.
7. Notate the locations of each smoke alarm, R314

If you have any questions, please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review
12/30/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/31/2020 SAMUEL ROGERS ZONING REVIEW Reqs Change FROM: Samuel Rogers
PDSD Zoning Review Section

PROJECT: T20CM08175 (Project Number)
100-amp RV & Trailer Panels and 50-amp Extension (1st Review)
4318 N Wegner Ln

TRANSMITTAL DATE: 12/31/20

DUE DATE: 12/10/20

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.


01. COMMENT: There appears to be several unpermitted structures on this site. All structures must be permitted to approve this permit.

02. COMMENT: If there are three or more residential units on this site it will be considered a commercial site. (If the structure labeled “existed storage” has a kitchen inside, it will be considered a residential unit). All structures proposed on commercial sites must be approved on a Development Package prior to the building permit’s approval. For development package info see below:

Development Package Application: https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf

Development Package Submittal checklist: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

Presubmittal Application (not required): https://www.tucsonaz.gov/files/pdsd/forms/Thursday_Pre-Submittal_Meeting_Application.pdf



If you have any questions about this transmittal, Contact Samuel Rogers at Samuel.Rogers@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised Building Plans