Permit Number: T20CM08171
Parcel: 132101340

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM08171
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/19/2020 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: Steve Shields
Section Manager

PROJECT: T20CM08171
2117 E Granito Vista
New Addition and Remodel
Residential (1st Review)

TRANSMITTAL DATE: November 19, 2020

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

1. Provide a lot coverage calculation that meets UDC Article 6.4.3.

2. Provide the property dimensions on the plan.

3. Indicate the zoning of the surrounding properties.

the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

4. Per UDC Table 6.3-2.A the minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line. Based on a wall height of less than 9’-0” the minimum perimeter yard setback to the south property line is 6’-0”, proposed setback is 5’-0”

5. Per UDC Article 6.4.5.C.1.a, the minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall. As a height dimension was not provided from grade to the highest point of the wall for the proposed porch setback requirements cannot be verified. Based on a measurement taken with Bluebeam it appears that this height is 14’ which requires 21’ perimeter yard setback to the street property line

Residential plot plan requirements can be found at https://www.tucsonaz.gov/pdsd/all-application-forms-submittal-requirements.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956
11/19/2020 SBLOOD1 ENGINEERING REVIEW Passed
11/19/2020 SSHIELD1 NPPO REVIEW Passed
11/19/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed