Permit Number: T20CM07850
Parcel: Unknown

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM07850
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/30/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/02/2020 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T20CM07850
Residential Addition
December 02, 2020
The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

1. Please resubmit your carport, porch, and patio addition plans with the following changes:

a. Add all setback information on the reference site plan. The new carport appears close to the property line and may not meet setback requirements. More information is needed to calculate the exact setback to the North.
b. The west (street) setback requirement is "20 feet or one and one-half the height of the proposed wall (H), measured from the street property line , whichever is greater" It appears that the new porch will be encroaching into the setback area. Please provide the setback information for the structure.
c. If you are unable to meet setbacks, a design development option (DDO) may be able to provide relief of setback requirements. The DDO application can be found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. Please be aware that the setback information will need to be on the plans before you can proceed with the DDO, if you choose to go that route.

2. Please show each structure on the property on the site plan. Aerial review shows a shed near the southeastern corner of the property. If the shed is no longer present, or is being removed, please indicate that information on the resubmittal.
3. Provide a floorplan of the residence showing each room on the property. In the R-1 zone commercial parking is required if the bedroom count exceeds 4. 5 bedrooms require 3 commercial parking spaces, and one space per additional room.

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
12/10/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change SHOW CARPORT SETBACK FROM PROPERTY LINE. POSTS REQUIRE A 3' SETBACK AND ROOF OVERHANG REQUIRES A 2' MINIMUM SETBACK WITHOUT A 1-HOUR RATED WALL FROM GROUND TO ROOF TOP.

SHOW ALL DWELLING DOORS AND WINDOWS OPENING INTO THE ENCLOSED REAR PATIO. BEDROOMS REQUIRE UNOBSTRUCTED EGRESS TO EXTERIOR.

SHOW BEAM & RAFTER SIZES FOR EACH STRUCTURE.

IDENTIFY THE SCREEN PANEL AND FASTENING AT DETAIL #8 & 11.