03/04/2022 STEVE SHIELDS ZONING REVIEW Reqs Change PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: T20CM07717
3668 E 4th Street – R-2
Detached Shed (2nd Review)

TRANSMITTAL DATE: March 4, 2022

The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. Provide a detailed comment response letter that clearly states how the following comments have been addressed.

The following comments need to be addressed prior to submitting for the Design Development Option (DDO).

1. This comment was not fully addressed. Provided the following information on the residential plot plan. Please resubmit the plans conforming to the requirements of the residential plot plan found at the following link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf
a. Provide the name of the owner & addressed on the plot plan.
b. Provide a lot coverage calculation the meets the requirements of UDC Article 6.4.3 and the example shown on the Residential Plot Plan Requirements on the plot plan.
c. Provide the height of the proposed shed on the plan so that perimeter yard setback requirements can be determined. Perimeter yard setbacks are based on a measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A.
d. Show all utilitie locations on the plot plan.
e. Indicated the zoning of the parcel and all adjacent parcels on the plot plan.
f. Provide the legal description : SPEEDWAY VIEW RESUB LOT 1” on the plot plan.

Per UDC TABLE 6.3-2.A: DIMENSIONAL STANDARDS FOR THE R-1, R-2, R-3, MH-1, & MH-2 ZONES, R-2 Zone, residential use to a residential zone, the required perimeter yard setback is 6’-0” or 2/3 (H), (H) = Height of the proposed exterior building wall, as measured from design grade to the highest point of the wall. Greater of the two dimensions applies. If all the wall heights are 9’-0” or less the minimum perimeter yard setback is 6’-0”, proposed setbacks from the shed to the south & west property lines are 2’-0”.

Once the above comments are addressed Zoning will be able to provide the needed comments for the processing of the DDO. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://www.tucsonaz.gov/pdsd-filedrop, using the Submission Type “Zoning Administration”. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.