Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T20CM07717
Parcel: 125112520

Address:
3668 E 4TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM07717
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/25/2020 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
Nicholas Martell, Planner
T20CM07717
Shed Permit
November 25, 2020

The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

1. Please resubmit the plans conforming to the requirements of the residential plot plan found at the following link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf

a. A full site plan with all setbacks, elevation drawings, lot coverage calculations and other plot plan standards is required.

b. Side and rear yard setbacks for the shed are 6' or 2/3 the height of the structure, whichever is greater.

c. The shed does not meet the required setbacks. A Design Development Option (DDO) is an application that can reduce the required setbacks. The application is found here: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

d. Another option is for the neighbors to the west and south to sign a setback waiver. If you choose that route, please print the following language on the site plan, with the neighbor information: "My Name is __________________ and I am the owner of the property located at ________________________. I have reviewed the site plan and I have no objection to structure being located or constructed ______ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________"

e. Please note, before any further steps are taken, the zoning review team requires a resubmittal of the plot plan with all the essential information, as well as confirmation of the following:

2. The maximum height of a detached accessory structure is 12 feet. Please show elevation drawings upon submittal in order for zoning to confirm the height.

a. If it is determined that the stucture exceeds height limitations, the shed can be attached to the residence with a 5' wide, 20 pound live load attachment.

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
11/25/2020 ANDREW CONNOR NPPO REVIEW Passed
11/30/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/09/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Passed