Permit Number: T20CM07519
Parcel: 14023039B

Address:
5858 S MORRIS BL

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM07519
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/23/2020 NMARTEL1 ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Nicholas Martell, Planner


PROJECT:T20CM07519



TRANSMITTAL: 11/23/2020
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9.

The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b).

The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a).

Because the property abuts more than one street, the owner chooses which street lot line is the front lot line. The building is already 30 feet from the property line to the east. Therefore, the southern lot line will be considered the side yard, resulting in a 10' setback.

If the applicant wishes to keep the existing ramada in the location shown on the site plan, a DDO will be required to reduce the setback to the south from 10' to 8'-6".

A DDO is required.

Alternatively, if the applicant does not wish to go through the DDO process, the 10' setback will need to be met to the south. Please reflect the changes on the site plan.

Regarding the site plan, there appears to be a shed on the northwestern part of the property that is not addressed on the site plan. It appears as if it is very close to the property line. If the shed is no longer there, or being removed, please indicate that on the next submittal. If the shed is still there, it needs to be addressed on the site plan.
11/24/2020 ANDREW CONNOR NPPO REVIEW Passed
11/27/2020 SBLOOD1 ENGINEERING REVIEW Passed
12/03/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
12/03/2020 JGARCIA1 APPROVAL SHELF Completed
12/03/2020 JGARCIA1 OUT TO CUSTOMER Completed
12/03/2020 JGARCIA1 REJECT SHELF Completed