Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM07495
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/30/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 09/01/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM07495 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. Items built without permit may require alteration or improvement for code compliance with the 2018 IRC, R105. Show the structure’s original construction and show proposed alterations for achieving code compliance. Provide a single set of plans in a .PDF file. Sample drawings are shown as an example: https://www.tucsonaz.gov/pdsd/residential-permits FLOOR PLANS: 1 Show a plan view showing slope of floor to the vehicle door. Show door locations and window sizes with type identified as XO or SH. SECTIONS - DETAILS: 1 Dimension the footing length, width, and depth of 12” into undisturbed soil for each footing type and condition, R403.1.1. Include continuous #4 rebar. 2 Show a cross-section detail of the proposed exterior wall, R106.1.1. Show 3/8” structural or ½” non-structural wall sheathing of the proposed exterior wall, R106.1.1. 3 Provide a wall detail showing a 6” minimum separation of exterior siding or sheathing above finished grade, R317.1 item 5. Also, show the weep screed with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. This may require a design with concrete stems. 4 Show roof (uplift resistance) fasteners (H2.5) with appropriate uplift capacity, R802.11 amended. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |