| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/27/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM07380 9743 E Quail Place Metal Fence Residential (1st Review) TRANSMITTAL DATE: November 27, 2020 This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10. 1. Provide a residential plot plan the meets the following requirements: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf Additional comments maybe forth coming once a plot plan is provided. 2. Provide a height dimension for the proposed metal fence, Per Unified Development Code (UDC) Article 6.6.2.I: The maximum height of a wall or fence within a perimeter yard shall be six feet; however, the wall or fence may be higher than six feet, but no higher than ten feet, if: (See Figure 6.6.1-A, Height of Wall or Fence within a Side or Rear Perimeter Yard.) 1. At least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron; 2. Part of, or located on top of, a retaining wall no higher than ten feet measured from design grade and no higher than six feet measured from the top of the retaining portion of the wall; 3. A greater height is required through the rezoning process or the special exception land use process; or, 4. A greater height is required by a specific UDC standard. As it does not appear that the proposed fence meets items 1 through 4 once the height is provided a Design Development Option (DDO) may need to be processed and approved. DDO requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 11/27/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 12/02/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | Provide an engineer’s calculation, design and seal for solid partition and screen walls exceeding 7’ in height above grade, R301.1.3. |