Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T20CM07345
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/29/2020 | JPEELDA1 | FIRE | REVIEW | Approved | |
11/10/2020 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | 1. Clarify the size of the horizontal drain exiting the new restrooms. It is labeled 3" on B/P3 but 4" on 1/P2 and 1/P1. Reference: Section 107.2.1, IPC 2018. 2. Provide urinal partitions in the new men's restroom. Reference: Section 405.3.5, IPC 2018. 3. Floor sinks in the kitchen shall discharge through a grease interceptor. Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson. 4. Hand sinks (SK-1) in the kitchen are allowed to connect to the sanitary waste system instead of the grease waste system only if each sink has a sign posted above it stating, "HANDWASH SINK ONLY! NO FOOD PREPARATION OR DISHWASHING ALLOWED." Reference: Section 1003.3, IPC 2018, as amended by the City of Tucson. 5. Revise the gas diagram to show the coffee roaster, D24, with an input of 140 MBH and the branch piping at 1" instead of ¾". Reference: Section 402.1, IFGC 2018. 6. The branch gas piping serving the existing AC unit (150 MBH @ 96 feet DL) is undersized, it should have a 1" supply. Reference: Section 402.1, IFGC 2018. |
11/10/2020 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Reqs Change | 1. Provide additional information from the roaster manufacturer regarding the vent for the coffee roaster: vent materials, positive or negative pressure venting, clearance from combustibles, chaff control, etc. Reference: Sections 301 and 304.1, IMC 2018. 2. Provide additional information from the wood-fired pizza oven manufacturer regarding the installation and maintenance of a chimney to vent the oven. Reference: Sections 301 and 304.1, IMC 2018. |
11/10/2020 | ROBERT SHERRY | WATER | REVIEW | Completed | |
11/13/2020 | DTRAMME1 | ENGINEERING | REVIEW | Passed | |
11/19/2020 | DAN SANTA CRUZ | ELECTRICAL-COMMERCIAL | REVIEW | Reqs Change | Please address the following electrical plan review comments. Also provide a written response. 1. Show locations of light switches in the remodeled restrooms. 2. Provide GFI protection for the receptacles in the kitchen and food prep areas. NEC 210 Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements. |
11/30/2020 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
11/30/2020 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
12/02/2020 | NICHOLAS ROSS | ZONING | REVIEW | Approved |