Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM07196
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/24/2020 | MALLORY RESS | ZONING | REVIEW | Reqs Change | FROM: Mallory Ress PDSD Zoning Review PROJECT: T20CM07196 2bdrm addition and carport addition- Building Plans (1st Review) 7533 E 34TH ST COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review comments were addressed. 1. COMMENT: The detached shed in the west side yard does not have zoning approval. You may add approval of this structure to this permit. You need to either get a Design Development Option approval or have the neighbor adjacent to the west sign the neighbor setback waiver. Language is pasted below. Ensure that the below language is put on the site plan, and the blanks are completed. The neighbor also needs to sign on the site plan 2. NEIGHBOR SETBACK WAIVER- TO BE INCLUDED AND COMPLETED ON THE SITE PLAN: My Name is and I am the owner of the property located at . I have reviewed the site plan and I have no objection to structure being located or constructed feet from the property line as depicted on the site plan. Signature: Date: 3. COMMENT: in the event that the adjacent neighbor will not sign the setback waiver, design development options comments may be forthcoming. In the alternative you may move the shed such that it is 6 feet back from the property line and not in the front yard. If you have any questions about this transmittal, please contact me at Mallory.Ress@tucsonaz.gov or you may contact Elisa Hamblin at Elisa.Hamblin@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: revised plans with setback waiver |
| 11/24/2020 | MRESS1 | ENGINEERING | REVIEW | Passed | |
| 11/24/2020 | MRESS1 | NPPO | REVIEW | Passed | |
| 11/24/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM07196 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: The City of Tucson adopted the 2018 IRC with amendments on 1/1/2019. Show the current code reference on the plans. STRUCTURAL PLANS: 1. Show the Glu Lam beam size with appropriate load carrying capacity, R301.1. A minimum 5-1/8” x 12 “ Glu Lam is required for this span and load. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. ELECTRICAL PLANS: 1. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside in the immediate vicinity. In addition to within bedrooms show a detector in the hallway. 2. Hallways of 10’ or more in length require a receptacle, E3901.10. 3. Protection of all interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors requires combination type arc-fault circuit interrupters, E3902.16. 4. Provide notation requiring tamper resistant receptacles for 125 volt, 15A and 20A receptacles, R4002.14. INTERNATIONAL ENERGY CONSERVATION CODE: 1. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and walls R=13. Show the “R” values of insulation and the maximum “U” factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.25, N1102.1. If you have any questions, please contact: Ken Van Karsen (520) 791-5550 City of Tucson Residential Plan Review |
| 12/16/2020 | JPEELDA1 | FIRE | REVIEW | Approved | Tucson water Fire Flow and hydrant was met per letter from Tucson Water dated 12-10-2020 in the CM folder. |