Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM07118
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2020 | LOREN MAKUS | ENGINEERING | REVIEW | Passed | |
| 10/19/2020 | NMARTEL1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell. Planner T20CM07118 416 N Shantel Dr Residential Addition October 19, 2020 The residential addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 1. The submitted plot plan is missing information. Follow the example of a residential plot plan using this link: https://www.tucsonaz.gov/files/pdsd/pdfs/Addition_Sample.pdf a. Address zoning information, lot coverage calculations, and elevation information as displayed on the plot plan link above. If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |
| 10/19/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations and additions. Place each plan sheet into a single PDF file. Use the Residential Plan Requirements & Checklist at https://www.tucsonaz.gov/pdsd/residential-permits Sample plans are available on request. PDSD-Residential@tucsonaz.gov SECTIONS - DETAILS: Provide structural details showing code compliant materials and fasteners from the foundation to the roof covering of new exterior walls. Include the foundation dimensions and floor separation from grade (6” minimum). Walls require compliant attachment (pressure treated sill) to a foundation (12” x 12” minimum) with spacing above exterior grade. PLUMBING PLANS: Provide piping details showing code compliant materials and sizes. MECHANICAL PLANS: Provide any new equipment details showing code compliant components, locations and sizes. ELECTRICAL PLANS: Provide any wiring details showing code compliant devices and sizes. Show circuit number and size with receptacles at all walls and lighting control at each doorway both interior and exterior. INTERNATIONAL ENERGY CONSERVATION CODE: Provide insulation details showing code compliant placement of materials and ratings (ceiling is R30), N1101. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 10/19/2020 | ANDREW CONNOR | NPPO | REVIEW | Passed |