Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T20CM07086
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/16/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building. Sample plans are available at https://www.tucsonaz.gov/pdsd/residential-permits Sample plans can be provided by e-mail request: pdsd-residential@tucsonaz.gov FLOOR PLAN: Provide a floor plan showing each room with labeled function. A SUNROOM requires a heat source if doors and windows are removed from dwelling entering the sunroom. Heating may be omitted if all openings have a means of closing stopping any airflow. ALL EXISTING BEDROOMS REQUIRE AN EGRESS TO EXTERIOR, therefore label the bedroom window near the kitchen as "not a bedroom room". Show a new function for the existing adjacent bedroom on the plan no longer having direct egress to the exterior. Show a exterior landing (slab) at the new exterior door. SECTIONS - DETAILS: Provide structural details showing code compliance. Show a pressure treated sill plate; 1/2" fasteners from the 12" deep foundation with #4 rebar. Include the foundation dimensions and 6" floor separation from grade. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review |
| 12/17/2020 | NMARTEL1 | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL Nicholas Martell, Planner T20CM07086 Residential Addition December 17, 2020 The residential plans have been reviewed by the Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed. 1. Please resubmit the plans and add the lot coverage calculations found at the following link: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov |