Review Date Reviewer's Name Type of Review Description Status Comments
10/13/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. The plans show a 1" water meter serving a total of 720 fixture units which equates to a demand of 164 GPM. A 1" water meter is limited to a maximum demand of 50 GPM; this installation will require a 3" water meter based on the current policy of Tucson Water.
2. The plans show three branches to distribute water to the mobile home park. With a maximum water velocity of 8 feet per second, 2" Schedule 40 PVC can handle only 84 GPM. Provide a breakdown of the fixture units for each section of the mobile home park and determine the required pipe sizes for the water mains serving each of the three branches.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/03/2020 PCAMARE1 OUT TO CUSTOMER Completed