Permit Number: T20CM06822
Parcel: 13608032E

Review Status: Completed

Review Details: COMMERCIAL - NEW

Permit Number - T20CM06822
Review Name: COMMERCIAL - NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/06/2020 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
10/06/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
10/06/2020 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved Please address the following electrical plan review comments. Also provide a written response.
1. Ref; Plan Sheet 16 of 25.
(a) Provide for a Grounding Electrode System or a grounding detail, and how it connects to the building ground grid. A concrete encased electrode installed in the concrete footing is mandatory in new building construction per NEC 250.52(3).
Ref; 2018 IBC sec, 107.2.1, 2017 NEC, 2018 IECC, City of Tucson Commercial Plan Submittal Requirements.
10/06/2020 ROBERT SHERRY WATER REVIEW Passed
10/06/2020 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Reqs Change 1. Sheet 1S1.00; Structural Notes (Codes and Standards): Note 1 indicates the 2012 and 2018 IBC. This project should be under the 2018 IBC only. Please verify.
2. Sheets 1S1.01, 1S1.02, and 1S2.01; Plans: Please add north arrows to all plans.
3. Structural Calculations; Page 1 (Building Codes): A note indicates the 2012 and 2018 IBC. This project should be under the 2018 IBC only. Please verify.
4. General: Please provide a Special Inspections Certificate with Parts A and B completed. This form may be found at www.tucsonaz.gov/PDSD.
5. General: Please provide written responses to all review comments.
10/06/2020 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
10/09/2020 ALEXANDRA HINES ZONING REVIEW Reqs Change RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Please resubmit updated drawings along with a detailed comment response letter, which states how all zoning review comments were addressed.

1. COMMENT: Zoning has reviewed the building plans for compliance with the unapproved development package (DP19-0069) and found that the building plans are consistent with the unapproved development package as it relates to the zoning requirements, which includes the building square footage, building height, building footprint, and location on the site.

2. COMMENT: Zoning will review the building plans on the next submittal to assure that any updates made to the building plans or the development package does not affect zoning requirements.

3. COMMENT: Zoning cannot approve the building plans until all PDSD commercial plans reviewers have also approved the building plans.

If you have any questions about this transmittal, Contact Alexandra Hines at alexandra.hines@tucsonaz.gov.
10/16/2020 LOREN MAKUS ENGINEERING REVIEW Approved
10/28/2020 JPEELDA1 FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/02/2020 PCAMARE1 OUT TO CUSTOMER Completed