Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T20CM06810
Parcel: 136031220

Address:
8607 E 24TH ST

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO

Permit Number - T20CM06810
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2020 NMARTEL1 ZONING REVIEW Reqs Change PDSD TRANSMITTAL
FROM: Nicholas Martell, Planner
PROJECT:T20CM06810
8607 E 24th St.
Privacy Screen

TRANSMITTAL DATE: October 12, 2020

The privacy screen wall plans have been reviewed by Zoning Review Section but cannot be approved until all zoning comments or concerns have been addressed.

1. The privacy screen is considered an accessory structure, and exceeds the maximim allowable height of a wall within a perimeter yard.

a. The privacy screen may exceed the 6 foot limit, but no higher than 10 feet if the height of a wall or fence within a side or rear perimter yard if at least 75% of the area above six feet in height is left unobstructed and open through the use of architectural elements such as arches, columns, or wrought iron. (6.6.2.I.1 udc).

b. If the above cannot be adhered to, the application of a design development option (DDO) can increase wall height up to 8 feet. https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf

c. The third option is to change the placement of the wall so it meets setback standards in the R-1 zone. The residential perimeter setback in the R-1 zone is 6' or 2/3 the height of the structure, whichever is greater (Table 6.3-2.A)

If you have any questions about this transmittal, please contact me at Nicholas.Martell@tucsonaz.gov
10/12/2020 NMARTEL1 ZONING REVIEW Reqs Change ZONING REVIEW TRANSMITTAL

FROM: Nicholas Martell
Planner

PROJECT:
Permit T20CM06810
Address 8607 E 24th Dt
Kelly Residence Screening Construction

TRANSMITTAL: 10/29/2020
COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1).

This site is located in the R-1 zone (UDC 4.7.1). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 10.

The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A).

The applicant is proposing a reduction in setbacks for a 7'6" screening wall on the EAST side of property from 6' to 1'-6".

A DDO is required
10/13/2020 ANDREW CONNOR NPPO REVIEW Passed
10/26/2020 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Reqs Change SOLID WALL STRUCTURE DESIGNS WITHOUT LATERAL SUPPORT REQUIRE AN ARIZONA STRUCTURAL ENGINEER STAMP WITH PERFORMANCE ANALYSIS, R301.1
11/04/2020 SBLOOD1 ENGINEERING REVIEW Passed