Permit Number - T20CM06689
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/19/2021 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | T20CM06689 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN: 1. Indicate the location and size of the water line supplying the guest house, R106.1.1. Show a minimum 1” line with shut off valve at the guest house, P2903.7. FLOOR PLANS: 1. Each detached structure requires a 3-foot fire separation distance from the 3-foot fire separation line around other buildings. One structure requires not less than one-hour fire-resistive construction (without openings) if placed less than six feet from an existing building, R302.1. Both structures require the rated construction when the separation is less than three feet. SECTIONS - DETAILS: 1. Show exterior wood siding, sheathing and wall framing with a 6” clearance above the ground, R317.1 item 5. Clarify detail #1/2. 2. Show the weep screed with a minimum clearance 4” above grade or 2” above paved areas, R703.7.2.1. May consider a design with concrete stems for detail #1/2. 3. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Update detail #2/4. MECHANICAL PLANS: 1. Update the whole-house mechanical ventilation description, R303.4; N1103.6 & M1505.4. Show the ZB80 exhaust fan with an appropriate flow rate setting on the plans. A two or three bedroom dwelling less than 1500 SF requires a 45 CFM continuous setting. ELECTRICAL PLANS: 1. Clarify if the electrical service line is overhead or underground on the Riser Diagram, E3608. Show a distribution panel on each building. 2. TEP usually requires the service panel on the property at the closest building to the service transformer. The overhead service conductor over the proposed building requires an 8’ clearance above the roof, E3604.2.1. 3. Designate the circuit number at the location of each light fixture, receptacle, appliance and equipment disconnect switch, E3404.12. 4. Smoke alarms are required outside each separate sleeping area, R314.3.2. Show a smoke alarm in each bedroom and outside in the immediate vicinity. Please contact the plans reviewer if you have any questions: Ken Van Karsen (520) 837-4912 PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review |
| 04/28/2021 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 04/29/2021 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Need to know the square footage of the house with porches and garages without the addition and the square footage of the new bathroom/walk in. Also need to know how far the farthest part of the guest house is from the closest hydrant. Jennifer.Peel-Davis@tucsonaz.gov 520-837-7033 |