Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T20CM06687
Parcel: 13608032E

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T20CM06687
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/01/2021 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
02/01/2021 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Reqs Change 1. Comment not resolved. An approved development plan is not to be used for construction. [Second comment: An approved development plan is not to be used for construction. Provide a site plan showing the location of the proposed building, existing structures on the site, distances to the lot lines and the established street grades as part of the shell drawing package. Reference: Sections 104.2 and 107.2.1, IBC 2018.] [Initial comment: Provide a site plan showing the location of the proposed building, existing structures on the site, distances to the lot lines and the established street grades. Reference: Section 107.2.6, IBC 2018.]
2. Comment not resolved. An approved development plan is not to be used for construction of on-site utilities. You may however include sheet C6.01 in the building plan set to resolve this problem. [Second comment: An approved development plan is not to be used for construction of on-site utilities (e.g. water service to the building, building sewer, etc.). Provide a site plan showing the installation of the water service to the building and the installation of the building sewer as part of the shell drawing package. Reference: Sections 104.2 and 107.2.1, IBC 2018.] [Initial comment: Provide a site drawing showing the size, route, and slope of the building sewer and the location of its connection to the public sewer. Reference: Section 107.2.6, IBC 2018.]
02/01/2021 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Completed
02/01/2021 ROBERT SHERRY WATER REVIEW Reqs Change Comment not resolved. An approved development plan is not to be used for construction of on-site utilities. You may however include sheet C6.01 in the building plan set to resolve this problem. [Second comment: An approved development plan is not to be used for construction of on-site utilities (e.g. water service to the building). Provide a site plan showing the installation of the water service to the building as part of the shell drawing package. Reference: Sections 104.2 and 107.2.1, IBC 2018.] [Initial comment: Provide a site drawing showing the size and route of the building water supply along with the location and size of both the water meter and the reduced pressure backflow preventer assembly. Reference: Section 107.2.1, IBC 2018.]
02/10/2021 DAN SANTA CRUZ ELECTRICAL-COMMERCIAL REVIEW Approved
02/11/2021 STEVE SHIELDS ZONING REVIEW Approved