Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Permit Number - T20CM06662
Review Name: RESIDENTIAL - BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/02/2020 | STEVE SHIELDS | ZONING | REVIEW | Reqs Change | PDSD TRANSMITTAL FROM: Steve Shields Section Manager PROJECT: T20CM06662 1506 W Stockwell Pl Attached Porch Residential (1st Review) TRANSMITTAL DATE: October 2, 2020 The room addition plans have been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. This site is located in the R-2 zone (UDC 4.7.9). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 1. Provide a plot that meets COT PDSD minimum standards. Plot plan requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Residential_Plot_Plan_Requirements.pdf If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
| 10/02/2020 | SSHIELD1 | ENGINEERING | REVIEW | Passed | |
| 10/02/2020 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 10/20/2020 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations and additions. Place each plan sheet into a single PDF file. Use the Residential Plan Requirements & Checklist at https://www.tucsonaz.gov/pdsd/residential-permits Sample plans are available on request. PDSD-Residential@tucsonaz.gov SITE PLAN: Provide a site plan showing all buildings and the size of the proposed patio, R106.1.1. Show setbacks to property lines and location of utility lines to the building. FRAMING PLAN: 2 x 6 rafters have a maximum span od 12 feet for a patio roof. SECTIONS - DETAILS: Provide structural details showing code compliant materials and fasteners from the foundation to the LOAD BEARING POINT AT THE HOUSE remove any stucco behind the ledger. Include the foundation dimensions (12" x 12") below grade and post separation from grade. Show a wheather proof covering. |